---
name: prepare-moving-meter-handover
description: "Organise moving-day meter readings for the old and new home by meter serial and register, flag missing, conflicting or unmapped readings, and prepare the records to give each supplier. Use when someone is moving house and needs closing and opening gas or electricity meter readings."
license: CC-BY-4.0
metadata:
  author: Raq.com
  version: "2026-11-22"
  homepage: https://skills.raq.com/skills/prepare-moving-meter-handover
---

# Prepare a moving-day meter handover

Organise opening and closing readings by property, meter and register and spot missing moving-day evidence before contacting a supplier.

## When to use this skill

- Someone is moving out and in on the same day and has photos of several meters to sort.
- A meter has more than one register, such as day and night or import and export, and the person is not sure which reading is which.
- The person wants to check they have every reading the suppliers will ask for before handing over the keys.

## When not to use it

- Submitting readings or opening accounts. The householder gives the readings to each supplier.
- Disputing a final bill or a previous occupant's debt. Use the supplier's complaints process with the dated readings.

## What you need

- Move date, each property's meter serials, fuel and expected registers.
- Dated photos or notes giving each register and reading, including units on the display.

## Ask before you start

If any of these are missing or unclear, ask before doing the work.

- What is the move date, and which meters, by serial number, are at each property? The serial is on the meter and usually on bills.
- Which registers should each electricity meter have: single rate, day and night, or import and export? Do you know which register is day and which is night?
- Does any gas meter read in cubic metres or in hundreds of cubic feet? The unit changes how the supplier bills the reading.

## Method

1. Split the evidence by property, old and new, before reading any numbers. Match each photo or note to a meter serial, not to the room or to how similar the meter looks. A supply-point identifier on a bill is not a meter serial.
2. List every register expected on each meter. Record the moving-day reading for each exactly as displayed, with leading zeroes, unit and display label, and keep the dated photo reference.
3. Keep import and export separate. Do not treat R1 and R2, or rate 1 and rate 2, as day and night without a confirmed mapping for that meter, because labels vary. If needed, suggest checking which register rises during the day.
4. Use a reading from another day only as supporting history, never as the moving-day figure. If two same-day records for one register disagree, mark it conflicting and ask for a clear second photo.
5. Build a closing set for the old property and an opening set for the new, keyed by property, serial and register. List missing, conflicting and unmapped readings separately.
6. Prepare the records for the householder to send: date, address, meter serial, register, reading and unit for each supplier. Do not submit anything. Remind them to tell both suppliers about the move and keep the dated photos in case the final bill is disputed.

## Checks before you deliver

- Two electricity registers on one meter need separate readings.
- A moving-day reading on the old meter cannot serve as the opening reading on a new meter with a different serial.
- Assuming R1 is the day rate. On many smart meters the first rate register is usually night or off-peak.
- Using a solar export reading as an import reading.
- Dropping leading zeroes, which changes the reading the supplier records.

## How to present the result

Start with whether the handover is complete: every expected reading present, or the exact registers still missing or unclear. Then give two short tables, closing readings for the old home and opening readings for the new, each with meter serial, register, reading, unit, date and photo reference. Finish with any reading to retake and a message ready to send each supplier.

## Worked example

**Request:** Prepare this handover for 2026-07-15.

**Supplied material:**

```text
Expected keys in order: Old/E72/day, Old/E72/night, New/E91/main.
15 July Old/E72/day 00124 kWh. 14 July Old/E72/night 00098 kWh. 15 July New/E91/main 07654 kWh.
```

**Answer:** 15 July 2026 closing reading, old meter E72: day 00124 kWh. The night register still needs a moving-day reading; 00098 is from 14 July.
Opening reading, new meter E91: 07654 kWh.

## Structured output for tests

For an ordinary job, answer in the format above and point back to the supplied evidence. Use this structure only for the test cases published with this skill, or when someone asks for structured JSON.

Return readings as an object keyed by the supplied property/serial/register key with the exact moving-day reading as text or null. Return missing and conflicting arrays of those keys in inventory order. A conflicting key goes only in conflicting. If a display has a reading but its tariff mapping is unknown, keep the named tariff key missing and include unmapped as an array of strings in source order. Each string contains the original display label, reading (with leading zeroes) and unit, separated by single spaces.

## Sources

- [Citizens Advice: moving home and your energy supply](https://www.citizensadvice.org.uk/consumer/energy/energy-supply/moving-home-your-energy-supply/moving-home-dealing-with-your-energy-supply/): Citizens Advice says to read the meters on the day you move out and the day you move in, give the readings to the relevant supplier, tell the supplier at least 48 hours before moving, and keep a record of readings and dates in case you disagree with the final bill.
- [Citizens Advice: reading a smart electricity meter](https://www.citizensadvice.org.uk/consumer/energy/energy-supply/your-energy-meter/how-to-read-your-smart-electricity-meter/): Shows that smart meter displays label rates differently, for example IMP R01 is usually night and R02 day, and suggests checking which register rises during the day when unsure. This is why the skill needs a confirmed mapping before labelling day and night.
- [GOV.UK: gas meter readings and bill calculation](https://www.gov.uk/gas-meter-readings-and-bill-calculation): Explains that imperial gas meters read in hundreds of cubic feet and metric meters in cubic metres, and how suppliers convert readings to kWh. This is why the skill records the unit shown on each gas meter.

Test cases and an answer checker for this skill: https://skills.raq.com/skills/prepare-moving-meter-handover
